DC BD1-63Z Miniature Circuit Breaker

DC BD1-63Z Miniature Circuit Breaker 500V C32 2P MCB

Key Features & Benefits
  • Professional MCB manufacturer for 12 years
  • Direct Factory Price with ODM / OEM Available
  • Excellent performance at temperature extremes
  • Standard IEC/EN60898-2 GB107932-2003
  • No. of poles: 1P, 2P, 4P
  • Excellent breaking ability
  • Dual wiring function of conductor and busbar
  • Energy storage operation, fast closure, long life
  • Convenient installation and disassembly
  • Contact on/off indication for higher security
  • Green environmental protection and energy saving
Product View 1 Product View 2 Product View 3 Product View 4

Technical Specifications

Type BD1-63Z
Rated Voltage Ue(V) 125V/250V DC(1P), 250V/500V DC(2P), 500V/1000V DC(4P)
Rated Current In(A) 1, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, 63
Rated Insulation Voltage Ui(V) 1000
Rated Impulse Withstand Voltage Uimp(kV) 4
Pole 1P, 2P, 3P, 4P
Type of Instantaneous Release C(7~10)In
Rated Short Circuit Breaking Capacity Icn(kA) 6
Mechanical and Electrical Life Mechanical life: 20,000 times; Electrical life: 1,500 times
Tightening Torque (N·m) 2.0
Class of Pollution Class 2
Protection Grade IP20
Installation Category II, III category

Over-Current Protection Property (Ref Temp 30°C)

Test Test Current Initial Status Test Time Expected Result Note
a 1.05In Cold position t ≤ 1h Non-release —
b 1.30In Carried out immediately after previous test t < 1h Release Current smoothly rises to specified value within 5s
c 7In Cold position t ≤ 0.2s Non-release —
d 10In Cold position t < 0.2s Release —

Applicable Conducting Wire

Rated Current (A) 1-6 10 16, 20 25 32 40, 50 63
Nominal Cross Section of Wire (mm²) 1 1.5 2.5 4 6 10 16

Power Consumption Per Pole of Circuit Breaker

Rated Current In(A) Maximum Power Consumption Per Pole (W)
1 ~ 10 2
13 ~ 32 3.5
40 ~ 63 5

DC Application Wiring Diagram

DC Application Wiring Diagram
Wiring Diagram Description:
  • L+: positive power supply, L-: negative power supply;
  • +: circuit breaker positive pole, -: circuit breaker negative pole;
  • DC power supply is usually “L-” grounding, positive and negative power supply system polarity “M” grounding.
  • It is strictly forbidden to remove the sealing plug of quadrupole products for wiring operation.

Dimension

Dimensions

Recommend Products

DC Fuse
DC Fuse
DC Isolator Switch
DC Isolator Switch
DC SPD
DC SPD

Certifications

Certifications

We Are Factory

Mday New Energy is a trusted manufacturer of protective components for photovoltaic systems across the globe. Our experience of working in the electrical industry for more than 12 years allows us to create solar DC components that comply with the latest DC standards. Through our focus on solar DC protection design, production, and marketing, we bring reliable brand-building PV protection solutions.

Factory Facilities

Independent Production of Accessories

All accessories of Mday are independently produced, including shells, copper parts, and varistor chips. Therefore, the quality and production cycle of each order can be fully guaranteed.

Injection Molding Workshop Automated Assembly Line Assembly Process Automated Line Detail

Injection Molding Workshop | Automated Assembly Line | Assembly Line

Own Test Laboratory

The laboratory is managed by highly qualified professionals, engineers, scientists, and experts in their respective fields, governed by dedicated modern techniques of management.

Test Laboratory
Demonstration of Different Tests
Demonstration of Different Tests
Variable Frequency Vibration Testing
Variable Frequency Vibration Testing
Physical Dimension Testing
Physical Dimension Testing

Automatic Production Line

We operate automatic production lines to precisely control the production cycle and quality of every order batch.

Automatic Production Line Overview
Automated Assembly Line
1. Automated Assembly Line
Robot Arm
2. Robot Arm
Product Testing
3. Product Testing
Laser or Pad Printing
4. Laser or Pad Printing
Heat-Wrapping
5. Heat-Wrapping
Packing
6. Packing

Frequently Asked Questions (FAQ)

Q: Are you a factory or trade company?
A: We are a factory and can provide OEM/ODM solutions tailored to your demands. Please feel free to check our factory video.
Q: When can I receive your quotation and detailed information after sending an inquiry?
A: All your inquiries will be replied to within 24 hours.
Q: How do you ensure MCB quality control?
A: Firstly, all raw materials are carefully selected for top quality. Secondly, skilled workers oversee every detail during production. Thirdly, our quality control department conducts dedicated process checks. Finally, all products are 100% tested under the ISO9001 system after production.
Q: What is the difference between a DC MCB and an AC MCB?
A: The main function is similar, but DC circuits are harder to interrupt and extinguish arcs. Therefore, the accessory configuration in DC models is higher grade than in AC models.
Q: How about the delivery term?
A: We maintain flexible stock levels depending on models. Please confirm directly with our sales representative to get exact delivery schedules.

Related Products