VDE, TÜV, and CE certified Type 1, Type 1+2, and Type 2 SPD modules engineered for Korean grid specifications.
Daejeon Metropolitan City stands as the undisputed central brain of South Korea’s scientific research, semiconductor testing, aerospace engineering, and green energy technology. Home to Daedeok Innopolis (Daedeok Research and Development Special Zone), KAIST, and numerous state-funded institutes such as the Korea Electrical Power Corporation (KEPCO) Research Institute, Daejeon operates an electrical ecosystem characterized by ultra-sensitive microelectronics, heavy-duty industrial test beds, and decentralized solar PV microgrids.
However, Daejeon's geography—surrounded by mountainous topography in the central Han River basin—exposes its electrical grid to seasonal lightning strikes during summer monsoons. High-density transient surges induced by direct atmospheric discharges threaten high-value research laboratories, commercial rooftop photovoltaic systems, and cleanroom power lines. For Korean procurement officers, EPC contractors, and electrical distributors operating in Daejeon, integrating IEC 61643-11 / KS C IEC 61643-11 compliant Type 1 Surge Protective Devices (SPDs) is not merely a precautionary measure—it is a critical requirement under the updated Korea Electrical Code (KEC).
Information Gain Key Insight for Korean Procurement Managers: Type 1 SPDs are specifically tested with a $10/350\,\mu\text{s}$ current impulse waveform ($I_{imp}$) designed to simulate direct lightning strikes. Installing lower-tier Type 2 devices ($8/20\,\mu\text{s}$ waveform) at main service entrances leaves critical automated testing equipment vulnerable to catastrophic thermal runaway and structural arc flashovers.
Engineered with heavy-duty Spark Gap and high-capacity Metal Oxide Varistor (MOV) tech capable of handling $I_{imp}$ up to 25kA per pole ($10/350\,\mu\text{s}$).
Full alignment with South Korea's national installation standards (KS C IEC 61643-11/31), ensuring seamless approval by KESCO electrical safety inspectors.
Maintains ultra-low clamping voltage ($U_p \le 1.5\,\text{kV}$), safeguarding delicate microprocessors, inverter boards, and PLCs installed across Daejeon's facilities.
To understand why wholesale buyers in Daejeon are transitioning to OEM Chinese suppliers with proven Type 1 and Type 1+2 technology, one must analyze the physical energy dissipation metrics. Transient overvoltages in industrial plants occur via two distinct mechanisms: direct lightning strikes to the external lightning protection system (LPS) or overhead lines, and indirect/induced surges caused by electromagnetic coupling.
Direct lightning strikes deliver energy over a prolonged duration. The $10/350\,\mu\text{s}$ test waveform reaches its peak current ($I_{imp}$) within $10\,\mu\text{s}$ and decays to 50% of peak amperage at $350\,\mu\text{s}$. The specific energy ($Q/R$) transferred by a 25kA $10/350\,\mu\text{s}$ strike is approximately 156.25 kJ/$\Omega$—more than ten times the thermal energy of an $8/20\,\mu\text{s}$ induced surge.
Our flagship Type 1 and Type 1+2 AC SPD series (MDH7) utilize advanced graphite spark gaps combined with high-energy zinc oxide varistors (MOV MYN34S). This hybrid arc-quenching architecture extinguishes the follow-current ($I_{fi}$) within milliseconds, preventing line-to-ground short circuits from blowing main supply fuses in Korean 380V/220V 3-phase 4-wire (TN-S / TN-C-S) distribution networks.
| Parameters | Type 1 Heavy Duty SPD | Type 1+2 Combined SPD | Type 2 Solar DC SPD |
|---|---|---|---|
| Test Standard Waveform | $10/350\,\mu\text{s}$ ($I_{imp}$) | $10/350\,\mu\text{s}$ & $8/20\,\mu\text{s}$ | $8/20\,\mu\text{s}$ ($I_n / I_{max}$) |
| Impulse Current ($I_{imp}$) | 12.5kA / 25kA per pole | 7kA / 12.5kA per pole | N/A (Inductive protection) |
| Nominal Discharge Current ($I_n$) | 30kA ($8/20\,\mu\text{s}$) | 20kA ($8/20\,\mu\text{s}$) | 20kA ($8/20\,\mu\text{s}$) |
| Maximum Discharge Current ($I_{max}$) | 60kA ($8/20\,\mu\text{s}$) | 50kA ($8/20\,\mu\text{s}$) | 40kA ($8/20\,\mu\text{s}$) |
| Voltage Protection Level ($U_p$) | $\le 2.0\,\text{kV}$ | $\le 1.5\,\text{kV}$ | $\le 2.8\,\text{kV} - 3.8\,\text{kV}$ |
| Core Internal Element | Hermetic Spark Gap / Heavy MOV | Integrated MOV + Thermal Fuse | High-density Zinc Oxide Varistor |
| Target Daejeon Application | Main Distribution Boards (MDB) | Sub-distribution & Cleanrooms | PV String Combiners & Inverters |
| Regulatory Certification | VDE / CE / IEC 61643-11 | TÜV / CE / KEC Ready | TÜV / UL 1449 / CE |
In semiconductor testing centers across Yuseong-gu, Daejeon, even a nanosecond transient spike can corrupt wafer diagnostics or burn expensive laser measuring instruments. Installing Type 1+2 SPDs (such as the Mday MDH7 1P 275V AC SPD) at the secondary low-voltage transformer output guarantees that external lightning strikes on KEPCO grid lines do not penetrate cleanroom power sub-panels.
Daejeon’s push toward carbon neutrality has accelerated rooftop PV array deployments across logistics centers in Daedeok Industrial Complex. Photovoltaic strings installed on expansive steel roofs act as large magnetic loops, collecting induced surge currents. Our Mday MLN40-DC T2 1000V Solar DC SPD and MDAY DC Breaker MQC-63DC provide dual protection: suppressing DC-side voltage transients while allowing safe isolation of string inverters during routine maintenance.
Daejeon’s smart transportation grid utilizes 350kW ultra-fast DC charging stations operating on high operating voltages. Switching surges from internal solid-state power switches, coupled with atmospheric discharges, can cause catastrophic damage to EV power modules. Wholesale installation of direct-factory Type 1 SPDs ensures uninterrupted charger availability and protects vehicle battery management systems (BMS).
In January 2021, South Korea officially adopted the KEC (Korea Electrical Code), fully harmonizing domestic electrical standards with IEC global guidelines. For Daejeon electrical engineering firms, key compliance rules include:
TÜV Rheinland onsite-verified manufacturer offering direct-factory pricing, full OEM/ODM branding, and short lead times for Daejeon importers.
Specialized exclusively in circuit protection components for PV, ESS, and low-voltage electrical systems. Our 55 certified staff operate 3 dedicated production lines in Yueqing Development Zone.
Our product lineup carries verified VDE, TÜV Rheinland, UL 248-19, and CE certifications. Every production batch undergoes 100% finished-product impulse testing before export.
Complete customization services including custom continuous voltage ($U_c$), customized housing colors, laser-printed customer logos, and pre-wired IP65 PV combiner box configurations.
Standard model inventories ship within 2 to 7 days. Streamlined export packaging ensures fast sea shipping directly to Busan or Incheon ports with seamless customs clearance for Daejeon clients.
Addressing key engineering, compliance, and ordering queries for wholesale partners in South Korea.
Under the revised Korea Electrical Code (KEC) and KS C IEC 62305, facilities fitted with external lightning protection or fed by exposed overhead lines require Type 1 SPDs at the main distribution board. Type 1 devices are certified to withstand direct $10/350\,\mu\text{s}$ impulse waves ($I_{imp} \ge 12.5\,\text{kA}$), preventing catastrophic fires and damage to downstream cleanroom microelectronics across Daedeok Innopolis.
Yes. We manufacture customized multi-pole SPD configurations (such as 3P+N / 4P) with maximum continuous operating voltages ($U_c$) tailored specifically for Korean nominal grid voltages (275V, 320V, 385V, 440V AC). This eliminates false tripping and thermal degradation caused by temporary overvoltages (TOV).
We supply both finished DIN-rail mounted SPDs (MDH7, MLN40 series) and individual core raw components like our TÜV-certified 34mm Square Metal Oxide Varistors (MYN34S MOV). This allows Daejeon-based panel builders and local SPD manufacturers to procure core raw materials or complete plug and play assemblies under one roof.
We provide full design-based and sample-based OEM customization. We offer laser printing of your Korean brand name, model numbers, custom barcode labels, customized enclosure colors, and localized Korean language instruction manuals with low minimum order quantities (MOQ from 50–200 pcs depending on model).
Standard catalogue items ship from our Wenzhou factory within 2 to 7 business days. Transit time via fast sea freight to Busan Port or Incheon Port typically takes only 2 to 4 days, ensuring Daejeon distributors maintain lean inventory with agile supply chain replenishment.